DESIGN PHASE: measurement
SUB ELEMENT NAME: photo measurement -
capacitor ac current measurement
VARIABLE NAME: [HEMTCAP]
DATE: REVISION LETTER: REVISION DATE:
APPLICABILITY: switching mode circuits or filter circuits
ACTIVITY: Measure (oscilloscope photographs) ac current through
and ac voltage across all capacitors with non-trivial ac currents
through them.
OUTPUT: Labeled photographs in laboratory notebook for later
comparison to specifications and analysis.
ALGORITHM:
[HEMTCAP] = engineer hours to measure capacitor currents
[HTMTCAP] = technician hours to measure capacitor currents
0.0 hours to make capacitor current measurements
DISCUSSION:
Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 25 February 2001
Copyright © 2001 Jerrold Foutz
All Rights Reserved